Описание оборудования | |
---|---|
Retroreflective sensor with polarization filter | |
General specifications | |
Effective detection range | 0 ... 17 m |
Reflector distance | 0.05 ... 17 m |
Threshold detection range | 21 m |
Reference target | H85-2 reflector |
Light source | LED |
Light type | modulated visible red light |
Polarization filter | yes |
Diameter of the light spot | approx. 290 mm at a distance of 17 m |
Angle of divergence | emitter 1.2° receiver 2° |
Ambient light limit | 80000 Lux |
Functional safety related parameters | |
MTTFd | 600 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means | |
Operation indicator | LED green |
Function indicator | 2 LEDs yellow, light up when light beam is free, flash when falling short of the stability control, off when light beam is interrupted |
Control elements | sensitivity adjustment (Adjustment to < 25% of the effective operating range) , Light-on/dark-on changeover switch |
Electrical specifications | |
Operating voltage | 12 ... 240 V AC/DC |
Power consumption | ? 3.5 VA |
Output | |
Switching type | light/dark on switchable |
Signal output | Relay, 1 alternator |
Switching voltage | max. 250 V AC/DC |
Switching current | max. 2 A |
Switching power | DC: max. 50 W AC: max. 500 VA |
Switching frequency | 25 Hz |
Response time | 20 ms |
Timer function | ON delay (GAN), OFF delay (GAB), one shot (IAB), ON delay-one shot (GAN-IAB), ON delay-OFF delay (GAN-GAB), programmable adjustment interval 0.1 ... 10 s |
Conformity | |
Product standard | EN 60947-5-2 |
Approvals and certificates | |
EAC conformity | TRCU 020/2011 TR CU 004/2011 |
Protection class | II, rated insulation voltage ? 250 V AC with pollution degree 1-2 according to IEC 60664-1 Output circuit insulated from control circuit in accordance with IEC61140. Caution! The protection class 2 is only valid when the terminal compartment is closed. |
UL approval | E87056 , cULus Listed Caution: This equipment is considered as open-type equipment. It must be mounted within an enclosure, that is suitably designed for protection against internal fire and personal injury resulting from accessibility to live parts according UL 508. |
CCC approval | Certified by China Compulsory Certification (CCC) |
Ambient conditions | |
Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) |
Storage temperature | -40 ... 75 °C (-40 ... 167 °F) |
Mechanical specifications | |
Housing width | 25.8 mm |
Housing height | 88 mm |
Housing depth | 65.5 mm |
Degree of protection | IP67 |
Connection | terminal compartment with 8 spring-loaded terminals for wire cross section 0.5 ... 1.5 mm2 , Insulation stripping 7.5 ... 8.5 mm , M16 x 1.5 cable gland |
Material | |
Mass | 112 g |
&n